dumplings (Windows, Desktop 2.31226.0 from the MSIX) saw "Claude Desktop
已不经过 magpie:配置已变更" while Desktop ran on magpie, and Reconnect
didn't clear it; switching Desktop's provider off magpie and back did.
Two causes:
- Check went over both sets of folders magpie writes for a packaged
Desktop (the package's LocalCache and the real ones, as which build
is installed can't be told) and failed when either was off magpie.
2.31226 reads the real %LOCALAPPDATA%\Claude-3p (bg5eau, already in
desktopdir), so the package's copy, emptied, isn't Desktop off
magpie. desktopRead now judges only the set whose Claude-3p Desktop
ran in last ("Local State", desktopdir.LastRun), every set when it
ran in none, as before.
- Reapply on an unwired drift re-set the field drift shows on and
fields on magpie's models. Desktop's drift shows on a tier (sonnet,
on a magpie model), and its provider field ("magpie") isn't a model,
so the gateway was never written back. Reapply now also re-sets a
field whose value is magpie itself, as Wired already counts it.
The reporter's analysis said 2.31226's AppxManifest excludes
Claude-3p from virtualization; that manifest wasn't seen here (the
Windows box has no MSIX Desktop), the fix rests on Desktop reading the
real Claude-3p, which bg5eau's case showed.
Run: TestClaudeDesktopMSIXChecksTheFoldersDesktopRuns (MSIX layout:
package Roaming\Claude and Local\Claude-3p with an older Local State,
the real Claude-3p newer); red with Check over every set, and red
with Reapply without the magpie-valued field. go test -tags nogui for
internal/agent, internal/desktopdir, internal/gui, internal/library;
the agent package's TestClaudeDesktop* built for windows/amd64 and run
on the Windows box, all pass; gofmt -l; go vet -tags nogui on darwin,
GOOS=linux and GOOS=windows for internal/agent, internal/desktopdir.