Files
magpie/docs
yetone c4f4aaaa97 gateway: Claude's bridge no longer passes hook notices and token counts on as the user's message (#2060)
Through the Claude subscription bridge, the inner Claude Code kept saying
"The user sent a new message while you were working:" followed by a hook's
additional context, a bare <total_tokens>... line or nothing at all. The
outer agent sends these after a tool result, and saidWithResults took every
text block after a result as words the user typed mid-turn and queued them
into the inner session.

Captured from a real Claude Code 2.1.296 with PreToolUse/PostToolUse hooks
against a local mock: after a tool_result it sends a {role:"system"}
message whose one text block joins "PreToolUse:Bash hook additional
context: ...", "PostToolUse:Bash hook additional context: ...", optionally
"The user sent a new message while you were working:\n<words>\n\nThis is how
Claude Code surfaces messages ...", and "<total_tokens>N tokens left
</total_tokens>". Older clients put the same in <system-reminder> blocks;
the reporter's had an empty reminder too, which is why some of their
"messages" were empty.

- saidWithResults takes only the user's words out of a mid-turn block
  (midTurnSaid, up to the client's own tail, a reminder's end, the token
  count or the next hook notice), skips the rest of a system or developer
  message, and drops a text that is an agent notice (agentNotice: empty
  once reminder tags are stripped, a hook notice of the known kinds, a
  token count, or one of the injected leads prompt.go already knows).
- renderParts, the sibling that labels text after a result as
  [user message] in the prompt for a fresh run, closes the result instead
  for an agent notice.
- docs/subsystems/claude-subscription-bridge.md says so.

Run:
- Fixtures are the literal 2.1.296 bytes and the reporter's
  (claude_hook_notice_test.go): nothing queued for hooks and token counts;
  only "also tell me the date" queued when the user did write; the
  rendered prompt has no [user message]. A "Stop hook is broken: fix it"
  typed by the user still goes on.
- With the old condition put back and the renderParts change off, the
  three new tests fail; restored, they pass.
- gofmt -l internal/: clean. go vet ./internal/gateway on darwin,
  GOOS=linux -tags nogui, GOOS=windows (set -o pipefail): clean.
- go test -count=1 -timeout 30m ./internal/gateway: ok (667s).
- Not tried end to end through the bridge with a real Claude subscription.
2026-10-14 09:32:21 +08:00
..