A Claude run on Windows was always claude -p, the entrypoint the plan counts at about twice the interactive mode's. The helper now starts Claude Code in a ConPTY there (child_windows.go): CreatePseudoConsole on two pipes, CreateProcess with the console attribute and STARTF_USESTDHANDLES with no handles. Without that flag a child takes the helper's own standard handles (the bridge's pipes) and draws into them, not the console. A .cmd claude is quoted by proc.Command as the -p run's. Ending closes the console, then kills after 3s; the -p fallback runs Claude Code as a child, as Windows has no exec. The pty code moved to child_unix.go unchanged, and tui.go has no build tag. Windows ends a run by killing its job, which no handler hears, so a turn's images folder is now removed once its message is sent, and a helper starting removes magpie-claude-images-* folders over an hour old (dropLeftImages). The gateway's gate lets Windows through (WSL stays -p), and the setting's text no longer says Windows is always -p (en, zh, zh-TW, ja, de). Doc updated. Run: - go test ./internal/claudetui on macOS (mote), Linux (magpie-desktop WSL2) and Windows 11 26200 (xiaomi-gpu): ok. The fake Claude Code on Windows is a claude.cmd, its console made raw with SetConsoleMode. New: TestDropLeftImages, and TestShimPastesImages checks the folder is gone after its message. - go test -run Claude ./internal/gateway on mote, and the TUI tests on Windows: ok. - i18n-keys and claude-tui-setting (chromium and webkit, en/zh/ja/de, 1100 and 420): 20 of 20 on the Windows box. On mote chromium passed and every webkit case timed out in browserType.launch, beside other sessions' GUI suites running for up to 20 hours (load 22). - go vet -tags nogui of claudetui, gateway and cli for darwin, linux and windows; gofmt -l clean. - Real account on xiaomi-gpu: a sandbox HOME gateway (port 3462) with the Claude Max account, real claude.exe 2.1.281, haiku-5-5. One tool call, two in one message, text then a call, and two image turns (twice): all right answers. 81 transcript rows, every one "entrypoint":"cli", no "-p" line in the log. Images noted as C:\Users\...\magpie-claude-images-*\image-N.png and no folder left. Killing the gateway ended its four resident helpers and claude.exe. The token wasn't refreshed; the copied credentials were deleted. (This ran before the 1809 check in start was added; the claudetui tests on Windows and GOOS=windows vet ran again after it: ok.) Broken by hand: STARTF_USESTDHANDLES removed, TestShimTurnsInteractive on Windows red (3 lines of 5 in 30s: the fake's drawing reached the shim's stdout). Not tried: an npm claude.cmd install with the real account (only the fake .cmd), Windows 10 before 1809 (no CreatePseudoConsole: the start checks for it and falls back to -p), a run ended mid-turn by the client on Windows. A stray "The system cannot find the path specified." showed once in the Windows test output; it wasn't on the shim's stderr, and three reruns didn't show it.
29 lines
1018 B
Go
29 lines
1018 B
Go
package claudetui
|
|
|
|
import (
|
|
"path/filepath"
|
|
|
|
"golang.org/x/sys/windows"
|
|
)
|
|
|
|
// fakeRaw makes the fake Claude Code's console raw, as the real one's is:
|
|
// keys read as they come, VT sequences in (a paste's brackets) and out.
|
|
func fakeRaw() {
|
|
in, _ := windows.GetStdHandle(windows.STD_INPUT_HANDLE)
|
|
var m uint32
|
|
if windows.GetConsoleMode(in, &m) == nil {
|
|
m &^= windows.ENABLE_LINE_INPUT | windows.ENABLE_ECHO_INPUT | windows.ENABLE_PROCESSED_INPUT
|
|
_ = windows.SetConsoleMode(in, m|windows.ENABLE_VIRTUAL_TERMINAL_INPUT)
|
|
}
|
|
out, _ := windows.GetStdHandle(windows.STD_OUTPUT_HANDLE)
|
|
if windows.GetConsoleMode(out, &m) == nil {
|
|
_ = windows.SetConsoleMode(out, m|windows.ENABLE_VIRTUAL_TERMINAL_PROCESSING)
|
|
}
|
|
}
|
|
|
|
// fakeScript is a batch file in dir that runs the test binary exe as the
|
|
// fake Claude Code, and its text: a .cmd, as npm installs Claude Code.
|
|
func fakeScript(dir, exe string) (string, string) {
|
|
return filepath.Join(dir, "claude.cmd"), "@set MAGPIE_TUI_TEST=claude\r\n@\"" + exe + "\" %*\r\n"
|
|
}
|