derrors (Linux Docker, 2 vCPU, v0.1.2281): every new Claude Code run
failed "Claude Code has not answered magpie's initialize request in 10s"
and the turn was 502 after 6 tries, while -p runs on the same account
answered.
Cause: the claude-tui-helper answers the bridge's initialize only once
the interactive Claude Code shows its prompt (claudetui.ready, up to
45s), or as -p after it falls back. The bridge gave it the 10s of any
control request and then ended it, so a Claude Code slower than 10s to
start was killed before its own -p fallback could run, and nothing was
marked: each try started the interactive mode again.
Fix:
- startRun waits tuiInitWait (claudetui.ReadyWait + 2x controlWait, 65s)
for a TUI run's initialize, and gives up on the request's context.
- a helper that still answers nothing is ended, the machine is marked
(claudetui.MarkBroken), and start runs the turn again as -p.
- claudePrintWhy goes -p at once while the mark holds ("the interactive
mode failed to start lately"), so no helper is started.
- the mark counts failed starts in a row: 30m after one, doubled to a
day (brokenFor), so a machine where it never starts waits about once a
day. A start that shows its prompt removes the mark.
- the helper falls back at once when Claude Code asks how to sign in
(a container signed in for -p only, CLAUDE_CODE_OAUTH_TOKEN), which
it otherwise took for the prompt or waited 45s on.
Every other control request keeps its 10s; initialize is the only one
a TUI run is sent (cliControl's one other caller is setSafeguards,
and a run with safeguards or cache marks is -p).
Run (mote, at this tree):
- go test ./internal/claudetui/ (whole package) ok
- go test ./internal/gateway/ -run Claude ok
- GOOS=linux and GOOS=windows go vet ./internal/claudetui/
./internal/gateway/ ok; gofmt -l clean
- wsl-run (magpie-desktop, Ubuntu 24.04): go test ./internal/claudetui/
./internal/gateway/ -run 'TestShim|TestBroken|TestClaudeTUI|
TestClaudeEndedRunSaysWhy|TestClaudeUnloadable' ok
Broken by hand (each red, then restored):
- TUI initialize waits controlWait, no mark, no retry (the old code):
TestClaudeTUISlowStartAnswered 502 "Claude Code has not answered
magpie's initialize request in 10s", the reporter's message
- TUI initialize waits controlWait only: marked broken, red
- no MarkBroken in the bridge, or no retry in start:
TestClaudeTUIHungHelperGoesPrint 502
- no sign-in check: TestShimFallsBackToPrint/asks_to_sign_in timed out
- no clearBroken: TestShimStartClearsBroken red
- brokenFor not doubling: TestBrokenGrows red
Not tried: a real Claude Code in a headless container, or any real
account. Why derrors' Claude Code was slow or stuck is not known: the
sign-in screen is a guess from -p working where the interactive mode
didn't; the helper's line now logs the screen it stopped on. No full
suite.